Category: Ventilators
CPX N830 ICU Ventilators
Weight: about 25kg including the trolley and the device, Operating temperature: 5-35˚ ,Relative humidity: 10% -90%. Power supply: AC input 100-240V, 50-60Hz, 8A Max; DC output: 24V, 3.33A.
Description
1. Scope of application:
For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive ventilation in hospital or at home.
2. The main function:
- Different treatment options can be provided according to patients’ needs, from CPAP to S, T,S / T, VGPS five
- With real-time monitoring8 kinds of respiratory
- With independent medical grade humidifier, better humidification and
- With oxygen cylinder slot easy to move the cylinder with
- Recording function (SD card).
- Maximum leak compensation function. 60L/m
- Adjustable trigger
- With full face
- With Trolley, easy to move the
- Alarm
3. The key technical parameters:
- Working mode: CPAP, S, T, ST,
- Ventilation parameters:
- Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval).
- Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval).
- Treatment pressure: 4-20 cmH2O (in CPAP mode, 5 cmH2O interval).
- Ramp: 0-45 minutes (interval of 5 minutes).
- Breathing rate: 5-50 times / minute (interval 1 time / minute).
- Inspiration time/ total breath time: 10-70% (interval of 1%).
- Rise time: 1-5 steps (1 step interval, 1 step rises fastest,5 steps rises most slowly).
- Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest).
- Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the slowest).
- Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml).
- VGPS(same with AVAPS,can set Target tidal volume)mode:
- Maximum IPAP value adjustable range: 4-30
- Minimum IPAP value adjustable range: 4-30
- EPAP value adjustable range: 4-30
- Target tidal volume: 50-1500ml.
4. Display range of monitoring setting parameters:
- Respiratory waveform can be
- Current mode: CPAP, S, T, ST,
- Inspiratory pressure: 4-30
- Expiratory pressure: 4-30
- Breathing frequency: 5-50 times /
- Inspiration time/ total breath time: 10-70%.
- Air leakage: 20-99.9lpm.
- Tidal volume: 50-1500ml.
- Minute ventilation: 0-50lpm.
- Ramp: 0-45
5. Alarm items:
- High pressure sound indication: Turn on/ off sound
- Low minute ventilation sound indication: Turn on/ off sound indication, can be set to 1-10L (interval 1L).
- Air leakage sound indication: on/
- Power failure sound indication: on/
- Asphyxia indication: On / off, asphyxia time can be set to 10-40 seconds (interval of 5 seconds).
- Low Tidal Volume Sound Indication: On / Off, Set Tidal Volume Value Range 50-500ml (Interval 50ml).
6. Specifications
- Weight: about 25kg including the trolley and the device
- Operating temperature: 5-35˚
- Relative humidity: 10% -90%.
- Power supply: AC input 100-240V, 50-60Hz, 8A Max; DC output: 24V, 3.33A.
Reviews